PDF Product Download: GMS Series – Coalescing Pre-Filter Membranes
Full Category Download: Guardian Membrane Separators (GMS Series) – Full Catalog
Full Category Download: Sample Conditioning – Analytical Filters (Full Catalog)
Guardian Membranes are also available with integrated coalescing pre-filters. A 50C-grade element is positioned upstream of the membrane to effectively remove the majority of liquids and particulates, thereby extending membrane life.
PDF Product Download: GMS Series – Coalescing Pre-Filter Membranes
Full Category Download: Guardian Membrane Separators (GMS Series) – Full Catalog
Full Category Download: Sample Conditioning – Analytical Filters (Full Catalog)
| PRODUCT FEATURES / BENEFITS |
|
|
|
|
|
|
|
Guardian Membranes are also available with integrated coalescing pre-filters. A 50C-grade element is positioned upstream of the membrane to effectively remove the majority of liquids and particulates, thereby extending membrane life. This all-in-one design minimizes dead volume, conserves panel space, and reduces potential leak points. These combination units are compatible with the same membrane kits used in our standard Guardian models. Corresponding part numbers can be found at the bottom of the attached chart.
Traditional T-Type
The GMS120/122 series features a traditional T-type design with an integrated coalescing pre-filter housed within the assembly. The GMS127G model adds a Pyrex bowl, enabling easy visual inspection of filter condition at a glance. In this series, the membrane is mounted on top with a vertical outlet, which helps maintain membrane cleanliness by promoting drainage.
A key feature of this series is its unique membrane holder plate, designed for easy maintenance. Once the collar is loosened and lifted, the plate slides out from underneath—allowing for quick membrane replacement without the need to disconnect any fittings.
Integral Coalescing High Flow Pre-Filter Membranes
The GMS130 Series builds on the proven design of our GMS120 Series, offering the same functionality with a physically larger membrane and coalescing element. The increased surface area of both components significantly extends service intervals, making it ideal for demanding or continuous sampling applications.
By integrating the coalescing filter and membrane into a single assembly, the GMS130 minimizes sample lag time, conserves panel space (one housing instead of two), and reduces the number of potential leak points by limiting connection interfaces.
Pyrex Bowl For Visual Monitoring
The GMS137G and GMS138G Series are low-pressure variants of the GMS130 Series, designed for applications where visual monitoring is essential. These models utilize the same large membrane and coalescing element as the GMS130 but feature a durable Pyrex® glass bowl for clear, at-a-glance inspection of liquid accumulation.
This design is ideal for systems requiring immediate visual confirmation of filter performance and liquid breakthrough, particularly in low-pressure environments.
Technical Details
Our porous membranes are manufactured from pure PTFE, offering exceptional chemical inertness and extremely low absorption characteristics. Designed for reliability across a wide range of applications, these membranes are available in two standard grades to suit various flow and fluid requirements:
| Coalescing Pre-Filter Membranes remove | PTFE Filter Housings remove | Stand-Alone Membrane Separators remove | Fast Loop Filters (All Models) remove | Miniature Guardian Separators remove | Shroud-Deflector Filter Housings remove | |
|---|---|---|---|---|---|---|
| Name | Coalescing Pre-Filter Membranes remove | PTFE Filter Housings remove | Stand-Alone Membrane Separators remove | Fast Loop Filters (All Models) remove | Miniature Guardian Separators remove | Shroud-Deflector Filter Housings remove |
| Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
| SKU | ||||||
| Rating | ||||||
| Price | ||||||
| Stock | ||||||
| Weight | N/A | N/A | N/A | N/A | N/A | N/A |
| Dimensions | N/A | N/A | N/A | N/A | N/A | N/A |
| Additional information | ||||||
| Description | Guardian Membranes are also available with integrated coalescing pre-filters. A 50C-grade element is positioned upstream of the membrane to effectively remove the majority of liquids and particulates, thereby extending membrane life. | PTFE filter housings are engineered specifically for applications requiring exceptional chemical resistance and minimal adsorption. These housings support a range of filter elements for both gaseous and liquid filtration. | The Guardian Membrane Series is engineered to provide complete removal of entrained liquids and solids from gas samples assuring sample integrity and protecting downstream analyzers. | Fast Loop Filters are engineered to minimize the time delay commonly associated with online analyzer sample systems. Unlike traditional three-port T-type designs, our Fast Loop configurations continuously flush the filter element of heavy contaminants while filtering only the sample stream. This design significantly reduces lag time and extends filter element life. | The GMS100 protects gas chromatographs and other online analyzers that require low sample flow rates from liquid and particulate contamination when only minimal amounts of liquid are present in the sample gas. The GMS100 assembly features a straight-through flow path, with the inlet port and drain positioned on the same plane. The clean sample outlet is located on the opposite plane, enhancing flow efficiency and reducing the risk of flooding. | A simple and effective method for prefiltering sample streams with high particulate content is the use of a shroud-deflector tube surrounding the outer wall of the filter element. This permanent shroud redirects the incoming flow, causing heavier debris to settle at the base of the housing. |
| Add to cart |