Standard OEM Size with Microfiber Element (DIF-BNxx)
Our standard DIF-BN series is by far the most commonly used size of DIF since it combines high efficiency filtration with low pressure drops in a compact package. Whether being used in an OEM cabinet, emission bench, or air monitor this little gem is an economical workhorse.
Standard Grade: DIF-BN50 (99.99% @ 0.01 Micron) – Other Grades Available: 30, 40, 60, 70, 80Technical Information
- 1/4" Inlet / Outlet
- 11.5cc of Volume
- 230ºF Maximum Temp. At 0 PSIG
- 125 PSIG of Maximum Pressure at 110ºF
- 100% Grilamid TR 55 Blue Nylon body
- Fluorocarbon Borosilicate Glass Microfiber Element
- Standard Gas Flow at 100 PSIG is 4.2 SCFM
-
Standard OEM Size with Stainless Steel Screen (DIF-BNxxSS)
For applications where high efficiency microfiber elements are not necessary, we offer inexpensive Stainless Steel Screens which are commonly used in portable emission analyzers, bulk contaminate removal and liquid sampling.
For Portable Emission Analyzers use DIF-BN50SS. Other Micron Sizes Available: 05, 10, 25, 100Technical Information
- 1/4" Inlet / Outlet
- 11.5cc of Volume
- 230ºF Maximum Temp. At 0 PSIG
- 125 PSIG of Maximum Pressure at 110ºF
- 100% Grilamid TR 55 Blue Nylon body
- 304 Stainless Steel Screen Element
- Standard Gas Flow at 100 PSIG is 4.2 SCFM
-
Standard OEM Size w/1/8” Straight Barb (Short Spigot) (DIF-BNxxSP-1/8”)
Our standard DIF-BN series is by far the most commonly used size of DIF since it combines high efficiency filtration with low pressure drops in a compact package. For applications with 1/8” tubing, using the same foot pattern and size, please specify DIF-BN50SP-1/8”.
Standard: DIF-BN50SP-1/8” (99.99% @ 0.01 Micron) – Other Grades Available: 30, 40, 60, 70, 80Technical Information
- 1/8" Tubing Connection on Inlet / Outlet
- 11.5cc of Volume
- 230ºF Maximum Temp. At 0 PSIG
- 125 PSIG of Maximum Pressure at 110ºF
- Material
- Body - 100% Grilamid TR 55 Blue Nylon
- Straight Barb - Natural Nylon
- Fluorocarbon Borosilicate Glass Microfiber Element
- Standard Gas Flow at 100 PSIG is 4.2 SCFM
-
Standard OEM Size with 1/8″ Elbow Barb (DIF-BNxx-1/8″-90)
Our standard DIF-BN series is by far the most commonly used size of DIF since it combines high efficiency filtration with low pressure drops in a compact package. This DIF is ideal for installations with restricted tubing connection space. Combinations of different size barbs are available upon request.
Standard Grade: DIF-BN50-1/8”-90 – Other Grades Available: 30, 40, 60, 70, 80Technical Information
- 1/8" Tubing Connection on Inlet / Outlet
- 11.5cc of Volume
- 230ºF Maximum Temp. At 0 PSIG
- 125 PSIG of Maximum Pressure at 110ºF
- Material
- Body - 100% Grilamid TR 55 Blue Nylon
- Elbow Barb - White Nylon
- Fluorocarbon Borosilicate Glass Microfiber Element
- Standard Gas Flow at 100 PSIG is 4.2 SCFM
-
Standard OEM Size For Chemical Compatibility (DIF-BKxx)
This series of DIF assemblies is constructed of virgin white kynar for corrosive applications. Compatible applications include (not limited to): sulfuric & hydrochloric acids, chlorine (gas or liquid), hydrogen peroxide, phenol, glycol, and ETO.
Standard Grade: DIF-BK50 (99.99% @ 0.01 Micron) – Other Grades Available: 30, 40, 60, 70, 80Technical Information
- 1/4" Inlet / Outlet
- 11.5cc of Volume
- 230ºF Maximum Temp. At 0 PSIG
- 125 PSIG of Maximum Pressure at 110ºF
- Virgin White Kynar body
- Fluorocarbon Borosilicate Glass Microfiber Element
- Standard Gas Flow at 100 PSIG is 4.2 SCFM
-
Indicating Standard OEM Size with (DIF-BN50I)
The DIF-BN50I contains a red dye that bleeds through the element to provide an accurate visual indication when oil is present. The red dye will permeate through the element upon oil saturation. One common application are HVAC control panels. This dye can be added to any of our microfiber elements.
Simply Order as DIF-BN50I.Technical Information
- 1/4" Inlet / Outlet
- 11.5cc of Volume
- 230ºF Maximum Temp. At 0 PSIG
- 125 PSIG of Maximum Pressure at 110ºF
- 100% Grilamid TR 55 Blue Nylon body
- Fluorocarbon Borosilicate Glass Microfiber Element
- Standard Gas Flow at 100 PSIG is 4.2 SCFM
-
Miniature OEM Size with Microfiber Element (DIF-MNxx)
The DIF-MN, mini DIF was designed specifically as a final last chance filter for critical equipment with a small footprint. They are ideally used for HVAC / Pneumatic temperature control protection.
Standard Grade: DIF-MN50 (99.99% @ 0.01 Micron) – Other Grades Available: 30, 40, 60, 70, 80Technical Information
- 1/4" Inlet / Outlet
- 6cc of Volume
- 230ºF Maximum Temp. At 0 PSIG
- 125 PSIG of Maximum Pressure at 110ºF
- 100% Grilamid TR 55 Blue Nylon body
- Fluorocarbon Borosilicate Glass Microfiber Element
- Standard Gas Flow at 100 PSIG is 2.1 SCFM
-
Miniature OEM Size with 1/8″ Straight Barb (DIF-MNxx1/8″)
Our mini DIF was designed specifically as a final last chance filter for critical equipment with a small footprint and 1/8”ID tubing. They are ideally used for HVAC/Pneumatic temperature control protection.
Standard: DIF-MN50-1/8” (99.99% @ 0.01 Micron) – Other Grades Available: 30, 40, 60, 70, 80Technical Information
- 1/8" Tubing Connection on Inlet / Outlet
- 6cc of Volume
- 230ºF Maximum Temp. At 0 PSIG
- 125 PSIG of Maximum Pressure at 110ºF
- Material:
- Body - 100% Grilamid TR 55 Blue Nylon
- Straight Barb - White Nylon
- Fluorocarbon Borosilicate Glass Microfiber Element
- Standard Gas Flow at 100 PSIG is 2.1 SCFM
-
Miniature OEM Size with 1/8″ Elbow Barb (DIF-MNxx-1/8″-90)
Our mini DIF was designed specifically as a final last chance filter for critical equipment needing a small footprint and 1/8”ID tubing at a 90° angle. Ideally used for HVAC/Pneumatic temperature control protection.
Standard Grade: DIF-MN50-1/8”-90 (99.99% @ 0.01 Micron) – Other Grades Available: 30, 40, 60, 70, 80Technical Information
- 1/8" Tubing Connection on Inlet / Outlet
- 6cc of Volume
- 230ºF Maximum Temp. At 0 PSIG
- 125 PSIG of Maximum Pressure at 110ºF
- Material:
- Body - 100% Grilamid TR 55 Blue Nylon
- Elbow Barb - White Nylon
- Fluorocarbon Borosilicate Glass Microfiber Element
- Standard Gas Flow at 100 PSIG is 2.1 SCFM
-
Intermediate OEM High Flow DIF w/ Microfiber Element (DIF-INxx)
Our intermediate range is utilized where higher particulate holding capacity is required.
Kynar Version Now Available: Designate “IK” Standard Grade: DIF-IK50
Standard Grade: DIF-IN50 (99.99% @ 0.01 Micron). Other Grades Available: 30, 40, 60, 70, 80Technical Information
- 1/4" Inlet / Outlet
- 50cc of Volume
- 230ºF Maximum Temp. At 0 PSIG
- 100 PSIG of Maximum Pressure at 110ºF
- 100% Grilamid TR 55 Blue Nylon body
- Fluorocarbon Borosilicate Glass Microfiber Element
- Standard Gas Flow at 100 PSIG is 10.0 SCFM
-
Intermediate OEM High Flow DIF with SS Screen (DIF-INxxSS)
For applications where high efficiency microfiber elements are not necessary, we offer inexpensive Stainless Steel Screens which are commonly used in portable emission analyzers, bulk contaminate removal and liquid sampling.
For Portable Emission Analyzers use DIF-BN50SS. Other Micron Sizes Available: 05, 10, 25, 100Technical Information
- 1/4" Inlet / Outlet
- 50cc of Volume
- 230ºF Maximum Temp. At 0 PSIG
- 100 PSIG of Maximum Pressure at 110ºF
- 100% Grilamid TR 55 Blue Nylon body
- 304 Stainless Steel Screen Element
- Standard Gas Flow at 100 PSIG is 10.0 SCFM
-
Intermediate OEM High Flow Coalescing DIF (DIF-INxxC)
Our intermediate DIF with 3rd spigot is utilized when coalescing (liquid removal) is required.
Kynar Version Now Available: Designate “IK”
Standard Grade: DIF-IK50C
Standard Grade: DIF-IN50C (99.99% @ 0.01 Micron). Other Grades Available: 30, 40, 60, 70, 80Technical Information
- 1/4" Inlet, Outlet, and Drain Port
- 50cc of Volume
- 230ºF Maximum Temp. At 0 PSIG
- 100 PSIG of Maximum Pressure at 110ºF
- 100% Grilamid TR 55 Blue Nylon body
- Fluorocarbon Borosilicate Glass Microfiber Element
- Standard Gas Flow at 100 PSIG is 10.0 SCFM
-
Large OEM Maximum Flow DIF w/ Microfiber Element (DIF-LNxx)
Our largest DIF is commonly specified where extreme amounts of particulate is present or for remote sites. Typical applications include ambient air monitoring.
Standard Grade: DIF-LN60 (99.5% @ 0.01 Micron) Other Grades Available: 30, 40, 50, 70, 80Technical Information
- 1/4" NPT Inlet / Outlet or 1/2" Slip On Connection
- 120cc of Volume
- 230ºF Maximum Temp. At 0 PSIG
- 100 PSIG of Maximum Pressure at 110ºF
- 100% Grilamid TR 55 Blue Nylon body
- Fluorocarbon Borosilicate Glass Microfiber Element
- Standard Gas Flow at 100 PSIG is 17.0 SCFM
-
Large OEM Maximum Flow DIF with SS Screen (DIF-LNxxSS-1/4″)
For applications where high efficiency microfiber elements are not necessary, we offer inexpensive Stainless Steel Screens which are commonly used in liquid sampling and pump protection.
For Liquid Sampling use DIF-LN50SS-1/4”. Other Micron Sizes Available: 05, 10, 25, 100Technical Information
- 1/4" NPT Inlet / Outlet or 1/2" Slip On Correction
- 120cc of Volume
- 230ºF Maximum Temp. At 0 PSIG
- 100 PSIG of Maximum Pressure at 110ºF
- 100% Grilamid TR 55 Blue Nylon body
- 304 Stainless Steel Screen Element
- Standard Gas Flow at 100 PSIG is 17.0 SCFM
-
Large OEM Maximum Flow Coalescing DIF (DIF-LNxxC)
Our large DIF with 3rd spigot is utilized when coalescing (liquid removal) is required.
Standard Grade: DIF-LN60C (99.5% @ 0.01 Micron) Other Grades Available: 30, 40, 50, 70, 80Technical Information
- 1/4" NPT Inlet / Outlet or 1/2" Slip On Connection
- 1/4" Drain Port
- 120cc of Volume
- 230ºF Maximum Temp. At 0 PSIG
- 100 PSIG of Maximum Pressure at 110ºF
- 100% Grilamid TR 55 Blue Nylon body
- Fluorocarbon Borosilicate Glass Microfiber Element
- Standard Gas Flow at 100 PSIG is 17.0 SCFM
-
Large OEM Maximum Flow DIF for Chemical Compatibility (DIF-LKxx)
The DIF-LK assemblies are constructed of black kynar for corrosive applications. Compatible applications include (not limited to): sulfuric & hydrochloric acids, chlorine (gas or liquid), hydrogen peroxide, Etc.
Standard Grade: DIF-LK60 (99.5% @ 0.01 Micron) Other Grades Available: 30, 40, 50, 70, 80Technical Information
- 1/4" NPT Inlet / Outlet or 1/2" Slip On Connection
- 120cc of Volume
- 230ºF Maximum Temp. At 0 PSIG
- 100 PSIG of Maximum Pressure at 110ºF
- Black Kynar body
- Fluorocarbon Borosilicate Glass Microfiber Element
- Standard Gas Flow at 100 PSIG is 17.0 SCFM
-
Large Maximum Flow DIF for Chemical Compatibility (DIF-LKxxPT)
The DIF-LK assemblies are constructed of black kynar for corrosive applications. Compatible applications include (not limited to): sulfuric & hydrochloric acids, chlorine (gas or liquid), hydrogen peroxide, Etc.
Standard Grade: DIF-LK25PT – Other Micron Available: 03PTTechnical Information
- 1/4" NPT Inlet / Outlet or 1/2" Slip On Connection
- 120cc of Volume
- 230ºF Maximum Temp. At 0 PSIG
- Black Kynar body
- Teflon (PTFE) Element
- Standard Gas Flow at 100 PSIG is 17.0 SCFM
-
Large OEM High Flow DIF with 1/4” Push Connect Fitting (DIF-LNxx-1/4″PTC)
This DIF is specified where extreme amounts of particulate is present and can easily replace the DIF-BN series. The filter comes complete with 1/4” push connect adapters (PTC).
Standard Grade: DIF-LN60-1/4”PTC (99.5% @ 0.01 Micron) Other Grades Available: 30, 40, 50, 70, 80Technical Information
- 1/4" Push Connect Fitting
- 120cc of Volume
- 230ºF Maximum Temp. At 0 PSIG
- 100 PSIG of Maximum Pressure at 110ºF
- 100% Grilamid TR 55 Blue Nylon body
- Fluorocarbon Borosilicate Glass Microfiber Element
- Standard Gas Flow at 100 PSIG is 17.0 SCFM