Housing Model | 130 | 132 | 134 | 136 | 140 | 142 | 144 | 146 |
---|---|---|---|---|---|---|---|---|
Port Size (NPT) | 1/4" | 1/2" | 1/4" | 1/2" | 1/4" | 1/2" | 1/4" | 1/2" |
Drain Type (NPT) | 1/4" | 1/4" | None | None | 1/4" | 1/4" | None | None |
Maximum Pressure (psig) | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 |
Internal Volume (cc) | 100 | 100 | 100 | 100 | 260 | 260 | 260 | 260 |
Weight of Housing (lbs) | 2.5 | 2.5 | 2.5 | 2.5 | 3.5 | 3.5 | 3.5 | 3.5 |
Principle Dimensions: (inches) | ||||||||
Center of Port to Head | 0.59 | 0.59 | 0.59 | 0.59 | 0.59 | 0.59 | 0.59 | 0.59 |
Head Diameter | 2.36 | 2.36 | 2.36 | 2.36 | 2.36 | 2.36 | 2.36 | 2.36 |
Overall Length | 4.80 | 4.80 | 4.80 | 4.80 | 9.33 | 9.33 | 9.33 | 9.33 |
Element Removal Clearance | 2.95 | 2.95 | 2.95 | 2.95 | 7.40 | 7.40 | 7.40 | 7.40 |
Maximum Temp. (400ºF) Standard Viton O-Ring | GV130 | GV130 | GV130 | GV130 | GV130 | GV130 | GV130 | GV130 |
Filter Element Codes: (1) Disposable Element (Standard) *Other Elements Available - View Drawing* | 25-64-x | 25-64-x | 25-64-x | 25-64-x | 25-178-x | 25-178-x | 25-178-x | 25-178-x |
Drawing **For More Detail & Options** | 130 | 132 | 134 | 136 | 140 | 142 | 144 | 146 |
Housing w/ PTFE Seals Maximum Temp. -PTFE (400ºF) Standard | 130S | 132S | 134S | 136S | 140S | 142S | 144S | 146S |
Features
- 316L Stainless Steel Construction
- Pressure to 1,500 PSIG, Temperature to 900ºF
- 3-Port Housings for Coalescing or Bypass Filtration
- High Pressure Models Available
- Available in Hastelloy, Monel, etc.
Applications
- CNG Filtration
- High Pressure Gas Production
- Sample Process Analyzers
- Supercritical CO2
- Food and Dairy Process
The 130 and 140 series of filters are ideal for use with gaseous and liquid sample process analyzers, as well as other demanding applications. The small internal volume, compact design, and positive O-ring sealing mechanism make them perfect for challenging applications. They are constructed entirely of 316L stainless steel and are free of welds to comply with NACE MR-01-75. For applications with higher flows and larger ports, please review our Model 150/160 series.
Product Bulletin Download