PTFE Filter Housings

The PTFE housings are designed especially for use in high chemical resistance and low adsorption applications. They accept disposable fluorocarbon elements for coalescing and particulate service, and sintered PTFE elements for particulate filtration only. The housings come standard with Viton O-rings, however Kalrez is recommended for the best chemical resistance.

A Pyrex glass bowl version is available which allows at-a-glance monitoring of the filtration process.

The assemblies may be utilized in gaseous or liquid filtration by simply installing the appropriate element. PTFE elements are recommended for liquid service with an outside to inside flow pattern so that the integral support core provides added strength and element life can be visually monitored.

Please keep in mind that the maximum pressure is 100 PSIG and the maximum temperature is 300°F regardless of O-ring material. We also offer exotics such as Monel, Hastelloy, Titanium and others which provide higher temperature and pressure ratings.

Features

  • PTFE & PTFE / Pyrex Glass Construction
  • Viton O-Ring Standard
  • Pyrex Glass Allows Instant Monitoring
  • Stainless Steel Head Band For Added Strength
  • Integral Support Core

Applications

  • Corrosive Applications
  • Environmental Service
  • Caustic Applications
TECHNICAL INFORMATION
Housing Model
120P | 122P
120PG | 122PG
Port Size (NPT)
1/8”" | 1/4”"
1/8" | 1/4”"
Drain Type (NPT)
1/8" |” 1/4”"
1/8" | 1/4”"
Maximum Pressure (psig)
100
100
Internal Volume (cc)
33
63
Maximum Temp. -Buna-N (1)
BN120P
BN120PG
Maximum Temp. -EPDM
GE120P
GE120PG
Maximum Temp. –Viton Standard
GV120P
GV120PG
Maximum Temp. -Silicone
GS120P
GS120PG
Maximum Temp. –Kalrez
KZ120P
KZ120PG
Weight of Housing (lbs)
0.5
1
Principle Dimensions: (inches)
Center Of Port To Head
0.39
0.59
Head Diameter
1.69
1.97
Overall Length
3.86
4.33
Element Removal Clearance
2.44
2.44
Filter Element Codes: (2)
Disposable Element
12-57-□
12-57-□
PTFE Element
PT-12-57-□
PT-12-57-□
Materials Of Construction:
Head
PTFE
PTFE
Bowl
PTFE
Pyrex
Internals
PTFE
PTFE
O-Rings (Standard)
Viton
Viton
Accessories:
Mounting Bracket
MBSS110
MBSS110
FLOW RATE IN SCFM FOR ABOVE ASSEMBLIES WITH GRADE 50C (3) or 70C (4)
Air Line Pressure120P Series
(PSIG)
50C70C
224
1537
30410
60717
80923
1001127

Notes:
(1) PTFE housing material limits temperature to 300°F regardless of O-Ring
(2) Replace ‘□’ with grade required, e.g. 12-57-50C, PT-12-57-03
(3) Flow rates for Grade 50C rated at 99.99% against 0.01 micron
(4) Flow rates for Grade 70C rated at 95% against 0.01 micron

.

TECHNICAL INFORMATION
Housing Model
130P | 132P
130PG | 132PG
140P | 142P
Port Size (NPT)
1/4"” | 1/2”"
1/4"” |1/2”"
1/4" |” 1/2”"
Drain Type (NPT)
1/4"” | 1/4”"
1/8"” | 1/8”"
1/4"” | 1/4”"
Maximum Pressure (psig)
100
100
100
Internal Volume (cc)
90
155
260
Maximum Temp. -Buna-N (1)
BN130P
BN130PG
BN140P
Maximum Temp. -EPDM
GE130P
GE130PG
GE140P
Maximum Temp. -Viton Standard
GV130P
GV130PG
GV140P
Maximum Temp. -Silicone
GS130P
GS130PG
GS140P
Maximum Temp. -Kalrez
KZ130P
KZ130PG
KZ140P
Weight of Housing (lbs)
1
2.00
3
Principle Dimensions: (inches)
Center Of Port To Head
0.59
0.59
0.59
Head Diameter
2.48
2.95
2.48
Overall Length
4.80
5.00
9.29
Element Removal Clearance
2.76
2.76
7.24
Filter Element Codes: (2)
Disposable Element
25-64-□
25-64-□
25-178-□
PTFE Element
PT-25-64-□
PT-25-64-□
PT-25-178-□
Materials Of Construction:
Head
PTFE
PTFE
PTFE
Bowl
PTFE
Pyrex
PTFE
Internals
PTFE
PTFE
PTFE
O-Rings (Standard)
Viton
Viton
Viton
Accessories:
Mounting Bracket
MBSS130
MBSS130
MBSS130
FLOW RATE IN SCFM FOR ABOVE ASSEMBLIES
WITH GRADE 50C (3) or 70C (4)
Air Line Pressure130P Series140P Series
(PSIG)
50C70C50C70C
23646
1561179
308161114
6013261823
8018382532
10021442835

Notes:
(1) PTFE housing material limits temperature to 300°F regardless of O-Ring
(2) Replace ‘□’ with grade required, e.g. 25-64-50C, PT-25-178-03
(3) Flow rates for Grade 50C rated at 99.99% against 0.01 micron
(4) Flow rates for Grade 70C rated at 95% against 0.01 micron

At the heart of our filter products is the filter element. Choosing the correct element insures proper results for your specific application:

Disposable Microfiber Elements

Disposable Microfiber Elements are most commonly used since they offer exceptional filtration, high flows with minimal pressure drops, and excellent chemical compatibility. These are ideal for use in sample conditioning, instrumentation, CNG, and Emission/Environmental service.

  • For Coalescing (liquid removal) and particle collection use our grade “C”. We recommend starting with the 70C which is rated at 95% efficient at 0.01 micron which provides outstanding filtration, at high flow rates.
  • For Particle removal only use grade “K”. We recommend starting with the 70K which is rated at 95% efficient at 0.01 micron which provides outstanding filtration, at high flow rates.
  • For Particulate removal above 300°F (150°C) use grade “S”.

Sintered PTFE

Sintered PTFE elements are used where only pure PTFE may contact the sample. They should be used in our PTFE series of housings based on the stainless steel models. Model 122P, 122PG, 130P, 130PG, 132P, 132PG, 142P.

Standard microns available: 3 and 25.

Sample Conditioning Filters

  • For Aggressive Service