1,500 PSIG Stainless Steel Housings

The 130 and 140 series of filters are ideal for use with gaseous and liquid sample process analyzers, as well as other demanding applications. The small internal volume, compact design, and positive O-ring sealing mechanism make them perfect for challenging applications. They are constructed entirely of 316L stainless steel and are free of welds to comply with NACE MR-01-75.

For applications with higher flows and larger ports, please review our Model 150/160 series listed at the bottom of this bulletin.

These housings are also available with a PTFE seal, which requires a modified sealing design: simply add an “S” to the housing code, e.g. 132S. PTFE seals cannot be retrofitted into standard housings originally having a Viton O-ring. A high temperature gasket can only be fitted into the S version housing.

Features

  • 316L Stainless Steel Construction
  • Pressure To 1,500 PSIG, Temperature To 900°F
  • 3-Port Housings For Coalescing Or Bypass Filtration
  • High Pressure Models Available
  • Available In Hastelloy, Monel, Etc.

Applications

  • CNG Filtration
  • Food And Dairy Process
  • Sample Process Analyzers
  • High Pressure Gas Production
TECHNICAL INFORMATION
Housing Model130132140142
Housing Model w/o Drain134136144146
Port Size (NPT)1/4”"1/2”"1/4”"1/2”"
Drain Type (NPT)1/4”"1/4”"1/4”"1/4”"
Maximum Pressure (psig)1500150015001500
Internal Volume (cc)110110265265
Maximum Temp. -Buna-N (250ºF)BN130BN130BN130BN130
Maximum Temp. -EPDM (300ºF)GE130GE130GE130GE130
Maximum Temp. -Viton (400ºF) StandardGV130GV130GV130GV130
Maximum Temp. -Silicone (450ºF)GS130GS130GS130GS130
Maximum Temp. -Kalrez (600ºF)KZ130KZ130KZ130KZ130
Weight of Housing (lbs)2.52.53.53.5
Principle Dimensions: (inches)
Center Of Port To Head0.590.590.590.59
Head Diameter2.362.362.362.36
Overall Length4.804.809.299.29
Element Removal Clearance2.952.957.407.40
Filter Element Codes: (1)
Disposable Element25-64-□25-64-□25-178-□25-178-□
Stainless Steel ElementSS-25-64-□SS-25-64-□SS-25-178-□SS-25-178-□
PEL ElementPEL-25-64-□PEL-25-64-□PEL-25-178-□PEL-25-178-□
PTFE ElementPT-25-64-□PT-25-64-□PT-25-178-□PT-25-178-□
Materials Of Construction: (2)
Head & Internals316LSS316LSS316LSS316LSS
Bowl316LSS316LSS316LSS316LSS
O-Rings (Standard)VitonVitonVitonViton
Accessories:
Mounting BracketMBSS130MBSS130MBSS130MBSS130
Support CoreSC130SC130SC140SC140
Housing Model w/ PTFE Seals130S132S140S142S
Maximum Temp. -PTFE (400ºF) StandardGP130SGP130SGP130SGP130S
FLOW RATE IN SCFM FOR ABOVE ASSEMBLIES
WITH GRADE 50C (3) or 70C (4)
Air Line Pressure130 Series140 Series
(PSIG)
50C70C50C70C
156111013
308161519
6013262532
10021444050
15029585568
250458983106
50087173163209
1500282524488627

Notes:
(1) Replace ‘□’ with grade required, e.g. 25-64-50C, PT-25-178-03
(2) Material abbreviations, 316LSS = 316L Stainless Steel
(3) Flow rates for Grade 50C rated at 99.99% against 0.01 micron
(4) Flow rates for Grade 70C rated at 95% against 0.01 micron

At the heart of our filter products is the filter element. Choosing the correct element insures proper results for your specific application:

Disposable Microfiber Elements

Disposable Microfiber Elements are most commonly used since they offer exceptional filtration, high flows with minimal pressure drops, and excellent chemical compatibility. These are ideal for use in sample conditioning, instrumentation, CNG, and Emission/Environmental service.

  • For Coalescing (liquid removal) and particle collection use our grade “C”. We recommend starting with the 70C which is rated at 95% efficient at 0.01 micron which provides outstanding filtration, at high flow rates.
  • For Particle removal only use grade “K”. We recommend starting with the 70K which is rated at 95% efficient at 0.01 micron which provides outstanding filtration, at high flow rates.
  • For Particulate removal above 300°F (150°C) use grade “S”.

Stainless Steel 5-Layer Mesh Elements

Stainless steel elements (SS) are designed for the filtration of heavily contaminated gas samples, CNG, and liquid streams since they are recleanable by back flushing or ultrasonic cleaning. Standard microns available: 0.5, 1, 3, 10, 25, 50, 100, and 200.

Sintered PTFE

Sintered PTFE elements are used where only pure PTFE may contact the sample. They should be used in our PTFE series of housings based on the stainless steel models. Model 122P, 122PG, 130P, 130PG, 132P, 132PG, 142P.

Standard microns available: 3,10, and 25.

Sintered Polyethylene (PEL)

Sintered polyethylene elements (PEL) are used only in non-corrosive applications to remove bulk contaminates. Standard micron sizes available: 10, 25, and 75.

  • NACE Complaint MR-01-75
  • Fuel Gas Filter
  • Wellhead Control Panel Filter
  • Accepts Microfiber, Stainless Steel, PTFE, & PEL Filter Elements

Our Gas and Liquid Process Filters protect equipment from sample impurities by removing solids and liquids from gases up to 99.999% efficiency at 0.01 micron. This series of filters is also ideal to use in liquid sample process applications by simply employing our pleated liquid elements, or stainless steel elements. A 1 micron efficiency can be reached in liquids with the aforementioned elements.

To satisfy the extreme wide range of requirements for process sample filters, we supply a complete line of filter elements in stainless steel, polypropylene, and other corrosion-resistant materials. A choice of high efficiency borosilicate microfiber filter elements, which are inert to most liquids and gases, are also offered.

Our 150 and 160 series of high-pressure 316L stainless steel filter housings offer exceptional value and performance. The threaded head to bowl connection with captured o-ring provides positive sealing even in very corrosive and demanding applications. The 1500 PSIG rating covers the majority of gas and liquid applications.

Features

  • Filters Gases & Liquids
  • 316L Stainless Steel
  • 1,500 PSIG / 400°F – Standard
  • 6,000 PSIG & Flanges Available
  • 3-Port Housings For Coalescing
  • Particulate Or Bypass Filtration

Applications

  • CNG Filtration
  • Blow Molding Equipment
  • Gas Production
  • Food And Dairy Processing
  • High Pressure Liquid Filters
TECHNICAL INFORMATION
Housing Model150*151152
Port Size (NPT)1”"1 1/2”"2”"
Drain Type (NPT)1/4”"1/4”"1/4”"
Maximum Pressure (psig)150015001500
Internal Volume (cc)150015001500
Maximum Temp. -Buna-N (250ºF)BN150BN150BN150
Maximum Temp. -EPDM (300ºF)GE150GE150GE150
Maximum Temp. -Viton (400ºF) StandardGV150GV150GV150
Maximum Temp. -Silicone (450ºF)GS150GS150GS150
Maximum Temp. -Kalrez (600ºF)KZ150KZ150KZ150
Weight of Housing (lbs)222222
Principle Dimensions: (inches)
Center Of Port To Head1.501.851.85
Head Diameter4.334.334.52
Overall Length14.7515.5815.58
Element Removal Clearance9.059.059.05
Filter Element Codes: (1)
Disposable Element51-230-□51-230-□51-230-□
Stainless Steel ElementSS-51-230-□SS-51-230-□SS-51-230-□
PEL ElementPEL-51-230-□PEL-51-230-□PEL-51-230-□
PTFE ElementPT-51-230-□PT-51-230-□PT-51-230-□
Materials Of Construction: (2)
Head & Internals316LSS316LSS316LSS
Bowl316LSS316LSS316LSS
O-Rings (Standard)VitonVitonViton
Accessories:
Mounting BracketMB150MB150MB150
Support CoreSC150SC150SC150
FLOW RATE IN SCFM FOR ABOVE ASSEMBLIES
WITH GRADE 50C (3) or 70C (4)
Air Line Pressure150 Series
(PSIG)
50C70C
153879
3056116
6093198
100151314
150209430
250319667
5006501334
150018973944

Notes:
(1) Replace ‘□’ with grade required, e.g. 51-230-50CS, PT-51-230-03
(2) Material abbreviations, 316LSS = 316L Stainless Steel
(3) Flow rates for Grade 50C rated at 99.99% against 0.01 micron
(4) Flow rates for Grade 70C rated at 95% against 0.01 micron
(*) Also available in 3/4”
.

TECHNICAL INFORMATION
Housing Model160*161162
Port Size (NPT)1”"1 1/2”"2”"
Drain Type (NPT)1/4”"1/4”"1/4”"
Maximum Pressure (psig)150015001500
Internal Volume (cc)270027002700
Maximum Temp. -Buna-N (250ºF)BN160/2BN160/2BN160/2
Maximum Temp. -EPDM (300ºF)GE160/2GE160/2GE160/2
Maximum Temp. -Viton (400ºF) StandardGV160/2GV160/2GV160/2
Maximum Temp. -Silicone (450ºF)GS160/2GS160/2GS160/2
Maximum Temp. -Kalrez (600ºF)KZ160/2KZ160/2KZ160/2
Weight of Housing (lbs)383838
Principle Dimensions: (inches)
Center Of Port To Head1.181.851.85
Head Diameter4.334.334.52
Overall Length24.7225.1225.12
Element Removal Clearance19.3717.8717.87
Filter Element Codes: (1)
Disposable Element51-476-□51-476-□51-476-□
Stainless Steel ElementSS-51-476-□SS-51-476-□SS-51-476-□
PEL ElementPEL-51-476-□PEL-51-476-□PEL-51-476-□
PTFE ElementPT-51-476-□PT-51-476-□PT-51-476-□
Materials Of Construction: (2)
Head & Internals316LSS316LSS316LSS
Bowl316LSS316LSS316LSS
O-Rings (Standard)VitonVitonViton
Accessories:
Mounting BracketMB150MB150MB150
Support CoreSC160SC160SC160
FLOW RATE IN SCFM FOR ABOVE ASSEMBLIES
WITH GRADE 50C (3) or 70C (4)
Air Line Pressure160 Series
(PSIG)
50C70C
156487
30125143
60160221
100256354
150354488
250546754
50010911508
150032484466

Notes:
(1) Replace ‘□’ with grade required, e.g. 51-476-50CS, PT-51-476-03
(2) Material abbreviations, 316LSS = 316L Stainless Steel
(3) Flow rates for Grade 50C rated at 99.99% against 0.01 micron
(4) Flow rates for Grade 70C rated at 95% against 0.01 micron
(*) Also available in 3/4” ports

At the heart of our filter products is the filter element. Choosing the correct element insures proper results for your specific application:

Disposable Microfiber Elements

Disposable Microfiber Elements are most commonly used since they offer exceptional filtration, high flows with minimal pressure drops, and excellent chemical compatibility. These are ideal for use in sample conditioning, instrumentation, CNG, and Emission/Environmental service.

  • For Coalescing (liquid removal) and particle collection use our grade “CS”. We recommend starting with the 70CS which is rated at 95% efficient at 0.01 micron which provides outstanding filtration, at high flow rates.
  • For Particle removal only use grade “K”. We recommend starting with the 70K which is rated at 95% efficient at 0.01 micron which provides outstanding filtration, at high flow rates.
  • For Particulate removal above 300°F (150°C) use grade “S”.

Stainless Steel 5-Layer Mesh Elements

Stainless steel elements (SS) are designed for the filtration of heavily contaminated gas samples, CNG, and liquid streams since they are recleanable by back flushing or ultrasonic cleaning. Standard microns available: 0.5, 1, 3, 10, 25, 50, 100, and 200.

Sintered PTFE

Sintered PTFE elements are used where only pure PTFE may contact the sample. They should be used in our PTFE series of housings based on the stainless steel models. Model 122P, 122PG, 130P, 130PG, 132P, 132PG, 142P.

Standard microns available: 3,10, and 25.

Sintered Polyethylene (PEL)

Sintered polyethylene elements (PEL) are used only in non-corrosive applications to remove bulk contaminates. Standard micron sizes available: 10, 25, and 75.

  • Ideal Compressed Natural Gas Filter
  • NACE Complaint MR-01-75 For Sour Service
  • Mechanical Seal Filter
  • Seal Gas Filtration
  • Accepts Microfiber, Stainless Steel, PTFE, & PEL Filter Elements

.
Our wide range of filter element materials and micron sizes allow multiple uses for these housings:

Gas Service Applications:Liquid Service Applications:
Coalescing and/or ParticulateParticulate
CNG FiltrationHigh Flow Sample Service
Blow Molding EquipmentFuel Filtration
Food Plant Caustic ServiceSolvents / Coolants
High Pressure Compressor ServiceCryogenic Service
General High Pressure Air ServiceCorrosive Environmental Service
Adsorption Cartridges; Carbon, Silica Gel, 13X, etc.Lubricants
Pleated for High Dirt Holding CapacityC.I.P. Service (Clean In Place)